Click the link below to download the file.
Get your files as below link
Dowload link
2A
12V
2A
87.5 x 35.0 x 55.0 mm
3.44” x 1.38” x 2.17”
0.13 kg (0.29 lb)
2A
12V
2A
87.5 x 35.0 x 55.0 mm
3.44” x 1.38” x 2.17”
0.13 kg (0.29 lb)
| Output Current 2A |
| Output Current 2A |
| Output Voltage 12V |
| Output Voltage 12V |
| Output Voltage Range |
| Output Voltage Range |
| Output Voltage Adjustment Range 10.8-13.2 Vdc |
| Output Power 24W |
| Output Power 24W |
| Output Current Adjustment Range |
| Output Current Adjustment Range |
| Max Output Voltage |
| Max Output Voltage |
| Buffering Time - |
| Line Regulation ± 0.5% @ 115 Vac & 230 Vac |
| Load Regulation ± 1.0% |
| PARD < 120 mVpp @ 0°C to +70°C < 360 mVpp @ -30°C to 0°C |
| Start-up Time 300 ms typ. @ 115 Vac & 230 Vac |
| Start-up Time 300 ms typ. @ 115 Vac & 230 Vac |
| Hold-up Time 14 ms typ. @ 115 Vac & 70 ms typ. 230 Vac (100% load) |
| Hold-up Time 14 ms typ. @ 115 Vac & 70 ms typ. 230 Vac (100% load) |
| Dynamic Response (Overshoot & Undershoot O/P Voltage) ± 10% @ 115 Vac & 230 Vac input, 10-100% load (Slew Rate: 2.5 A/μS, 50% duty cycle @ 5 Hz & 10 kHz) |
| Dynamic Response (Overshoot & Undershoot O/P Voltage) ± 10% @ 115 Vac & 230 Vac input, 10-100% load (Slew Rate: 2.5 A/μS, 50% duty cycle @ 5 Hz & 10 kHz) |
| Start-up with Capacitive Loads 8,000 µF max. |
| Start-up with Capacitive Loads 8,000 µF max. |
| Remote ON/OFF - |
| Remote ON/OFF - |
| Protective Device - |
| Protective Device - |
| Voltage Drop Between Input and Output - |
| Voltage Drop Between Input and Output - |
| Residual Ripple/PARD (20MHz) - |
| Residual Ripple/PARD (20MHz) - |
| Residual Ripple - |
| Residual Ripple - |
| Max. Power - |
| Max. Power - |
| Ripple & Noise - |
| Ripple & Noise - |
| LED System Voltage Range in CC Mode - |
| LED System Voltage Range in CC Mode - |
| Rise Time 30 ms typ. @ 115 Vac & 230 Vac |
| Rise Time 30 ms typ. @ 115 Vac & 230 Vac |
| Power Boost Duration - |
| Power Boost Duration - |
| Power Boost Recovery Time - |
| Power Boost Recovery Time - |
| Peak Power - |
| Peak Power - |
| Nominal Input Voltage 100-240 Vac |
| Nominal Input Voltage 100-240 Vac |
| Input Voltage Range 85-264 Vac |
| Input Voltage Range 85-264 Vac |
| Max Input Voltage - |
| Max Input Voltage - |
| Nominal Input Frequency 50-60 Hz |
| Nominal Input Frequency 50-60 Hz |
| Input Frequency Range 47-63Hz |
| Input Frequency Range 47-63Hz |
| Nominal DC Input Voltage |
| Nominal DC Input Voltage |
| DC Input Voltage Range - |
| DC Input Voltage Range - |
| Input Current < 0.7 A @ 115 Vac < 0.5 A @ 230 Vac |
| Input Current < 0.7 A @ 115 Vac < 0.5 A @ 230 Vac |
| Input Power (Standby Mode) - |
| Input Power (Standby Mode) - |
| Efficiency at 100% load 86.5% typ. @ 115 Vac 87.0% typ. @ 230 Vac |
| Efficiency at 100% load 86.5% typ. @ 115 Vac 87.0% typ. @ 230 Vac |
| Inrush Current 40 A typ. @ 230 Vac |
| Inrush Current 40 A typ. @ 230 Vac |
| Charging Time - |
| Charging Time - |
| Power Factor at 100% load - |
| Power Factor at 100% load - |
| Leakage Current < 0.25 mA @ 240 Vac |
| Leakage Current < 0.25 mA @ 240 Vac |
| Nominal Current - |
| Nominal Current - |
| Total Harmonic Distortion - |
| Total Harmonic Distortion - |
| Power Dissipation 0% load: 0.1 W typ. @ 115 Vac & 230 Vac |
| Power Dissipation 0% load: 0.1 W typ. @ 115 Vac & 230 Vac |
| Efficiency @ 10% load - |
| Efficiency @ 10% load - |
| Input Voltage Phase - |
| Input Voltage Phase - |
| Average Efficiency - |
| Average Efficiency - |
| No Load Power Consumption - |
| No Load Power Consumption - |
| Case Chassis / Cover Plastic | |
| Case Chassis / Cover Plastic | |
| Indicator Green LED DC OK | |
| Indicator Green LED DC OK | |
| Cooling System Convection | |
| Cooling System Convection | |
| Input Terminal M2.5 x 2 Pins (Rated 300 V / 16 A) | |
| Input Terminal M2.5 x 2 Pins (Rated 300 V / 16 A) | |
| Output Terminal M2.5 x 2 Pins (Rated 300 V / 16 A) | |
| Output Terminal M2.5 x 2 Pins (Rated 300 V / 16 A) | |
| Signal Terminal - | |
| Signal Terminal - | |
| Noise Sound Pressure Level (SPL) < 25 dBA | |
| Noise Sound Pressure Level (SPL) < 25 dBA | |
| Input/Output Terminal - | |
| Input/Output Terminal - | |
| Signal - | |
| Signal - | |
| Mounting Rail Standard TS35 DIN Rail in accordance with EN 60715 | |
| Mounting Rail Standard TS35 DIN Rail in accordance with EN 60715 | |
| Wire Input: AWG 24-12 Output: AWG 24-12 | |
| Wire Input: AWG 24-12 Output: AWG 24-12 | |
| Protection Structure - | |
| Protection Structure - | |
| Terminal - | |
| Terminal - | |
| Unit Weight 0.13 kg (0.29 lb) | Dimensions 87.5 x 35.0 x
55.0 mm 3.44” x 1.38” x 2.17” |
| Vibration (Operating) IEC 60068-2-6, Sine Wave: 10 Hz to 500 Hz @ 2 G; 10 min per cycle, 60 min for X, Y, Z direction |
| Vibration (Operating) IEC 60068-2-6, Sine Wave: 10 Hz to 500 Hz @ 2 G; 10 min per cycle, 60 min for X, Y, Z direction |
| Shock Test (Operating) - |
| Shock Test (Operating) - |
| Operating Temperature -40°C to +70°C |
| Operating Temperature -40°C to +70°C |
| Storage Temperature -40°C to +85°C |
| Storage Temperature -40°C to +85°C |
| Power De-rating Temperature: > 50°C de-rate power by 2% / °C Input Voltage: < 100Vac de-rate power by 1% / Vac |
| Power De-rating Temperature: > 50°C de-rate power by 2% / °C Input Voltage: < 100Vac de-rate power by 1% / Vac |
| Operating Humidity 5 to 95% RH (Non-Condensing) |
| Operating Humidity 5 to 95% RH (Non-Condensing) |
| Shock Test (Non-Operating) IEC 60068-2-27, Half Sine Wave: 50 G for duration of 11 ms; 3 times per direction |
| Shock Test (Non-Operating) IEC 60068-2-27, Half Sine Wave: 50 G for duration of 11 ms; 3 times per direction |
| Vibration (Non-Operating) - |
| Vibration (Non-Operating) - |
| Storage Humidity - |
| Storage Humidity - |
| Operating Altitude 0 to 5,000 Meters (16,400 ft) |
| Operating Altitude 0 to 5,000 Meters (16,400 ft) |
| Pollution Degree 2 |
| Pollution Degree 2 |
| Bump Test (Operating) - |
| Bump Test (Operating) - |
| Over Voltage Category II (Compliance to EN 62477-1 OVC III with 2,000 Meters altitude) |
| Over Voltage Category II (Compliance to EN 62477-1 OVC III with 2,000 Meters altitude) |
| Corrosion - |
| Corrosion - |
| Shock - |
| Shock - |
| Vibration - |
| Vibration - |
| Acoustic Noise - |
| Acoustic Noise - |
| Overvoltage < 18 V, SELV Output, Latch Mode |
| Overvoltage < 18 V, SELV Output, Latch Mode |
| Overload / Overcurrent 101 - 150% of rated load current, Auto-recovery Continuous current limit Mode (Vo > 80%) |
| Overload / Overcurrent 101 - 150% of rated load current, Auto-recovery Continuous current limit Mode (Vo > 80%) |
| Over Temperature Latch Mode |
| Over Temperature Latch Mode |
| Short Circuit Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) |
| Short Circuit Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) |
| Reverse Polarity Protection - |
| Reverse Polarity Protection - |
| Degree of Protection IP20 |
| Degree of Protection IP20 |
| Protection Against Shock Class II (No Primary Earth connection is required) |
| Protection Against Shock Class II (No Primary Earth connection is required) |
| Input Polarity Protection - |
| Input Polarity Protection - |
| Battery Polarity Protection - |
| Battery Polarity Protection - |
| Wrong Battery Voltage Protection - |
| Wrong Battery Voltage Protection - |
| Deep Discharge Protection - |
| Deep Discharge Protection - |
| Overload - |
| Overload - |
| Overcurrent - |
| Overcurrent - |
| Internal Fuse T3.15 A / 250 V |
| Internal Fuse T3.15 A / 250 V |
| Insufficient Input Voltage Protection - |
| Insufficient Input Voltage Protection - |
| Pollution Degree - |
| Pollution Degree - |
| MTBF Telcordia SR-332: > 700,000 hrs I/P: 115 Vac & 230 Vac, O/P: 100% load, Ta: 25°C |
| MTBF Telcordia SR-332: > 700,000 hrs I/P: 115 Vac & 230 Vac, O/P: 100% load, Ta: 25°C |
| Expected Cap Life Time 10 years (115 Vac & 230 Vac, 50% load @ 40°C) |
| Expected Cap Life Time 10 years (115 Vac & 230 Vac, 50% load @ 40°C) |
| Case Temperature Rise - |
| Case Temperature Rise - |
| Safety Certificate - |
| Safety Certificate - |
| Electrical Safety CB scheme: IEC 62368-1, IEC/EN/BS EN 61010-1/-2-201, IEC 60335-1, IEC/EN/BS EN 61558-1/-2-16 TUV Bauart: EN/BS EN 62368-1, EN/BS EN 60335-1 UL/cUL: UL 62368-1, UL 61010-1/-2-201 EAC: TP TC 004/2011 BSMI: CNS 15598-1 BIS: IS 13252 (Part 1) CCC: GB 4943.1 |
| Electrical Safety CB scheme: IEC 62368-1, IEC/EN/BS EN 61010-1/-2-201, IEC 60335-1, IEC/EN/BS EN 61558-1/-2-16 TUV Bauart: EN/BS EN 62368-1, EN/BS EN 60335-1 UL/cUL: UL 62368-1, UL 61010-1/-2-201 EAC: TP TC 004/2011 BSMI: CNS 15598-1 BIS: IS 13252 (Part 1) CCC: GB 4943.1 |
| CE In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU |
| CE In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU |
| Medical Safety - |
| Medical Safety - |
| Galvanic Isolation Input to Output 4.0 kVac |
| Galvanic Isolation Input to Output 4.0 kVac |
| Industrial Control Equipment - |
| Industrial Control Equipment - |
| Hazardous Location / ATEX - |
| Hazardous Location / ATEX - |
| II 3 G ATEX 2014/34/EU - |
| II 3 G ATEX 2014/34/EU - |
| Electrical Equipments of Machines - |
| Electrical Equipments of Machines - |
| Electrical Equipment for Use in Electrical Power Installations - |
| Electrical Equipment for Use in Electrical Power Installations - |
| Safety Entry Low Voltage - |
| Safety Entry Low Voltage - |
| Maritime - |
| Maritime - |
| Material and Parts - |
| Material and Parts - |
| Isolation Resistance - |
| Isolation Resistance - |
| PE Resistance - |
| PE Resistance - |
| UKCA In conformance with Electrical Equipment (Safety) Regulations 2016 and Electromagnetic Compatibility Regulations 2016 |
| UKCA In conformance with Electrical Equipment (Safety) Regulations 2016 and Electromagnetic Compatibility Regulations 2016 |
| Certificates for Other Countries - |
| Certificates for Other Countries - |
| BIS - |
| BIS - |
| KC - |
| KC - |
| Electrical Equipment for Measurement, Control, and Laboratory Use - |
| Electrical Equipment for Measurement, Control, and Laboratory Use - |
| ITE Safety - |
| ITE Safety - |
| SIL3 - |
| SIL3 - |
| CE/UKCA - |
| CE/UKCA - |
| Emission CISPR 32, EN/BS 55032, AS/NZS CISPR32, EN 61204-3, KS C 9832 Compliance to FCC Title 47, EN/BS 61000-6-3 , EN/BS EN 61000-6-4: Class B |
| Emission CISPR 32, EN/BS 55032, AS/NZS CISPR32, EN 61204-3, KS C 9832 Compliance to FCC Title 47, EN/BS 61000-6-3 , EN/BS EN 61000-6-4: Class B |
| Immunity EN/BS 55035, KS C 9835, EN/BS 61000-6-2 Compliance to EN 61000-6-1 |
| Immunity EN/BS 55035, KS C 9835, EN/BS 61000-6-2 Compliance to EN 61000-6-1 |
| Harmonic Current Emissions IEC/EN 61000-3-2, Class A |
| Harmonic Current Emissions IEC/EN 61000-3-2, Class A |
| Voltage Fluctuation and Flicker IEC/EN 61000-3-3 |
| Voltage Fluctuation and Flicker IEC/EN 61000-3-3 |
| ESD Immunity - |
| ESD Immunity - |
| Radiated Immunity - |
| Radiated Immunity - |
| EFT - |
| EFT - |
| Surge - |
| Surge - |
| Conducted Immunity - |
| Conducted Immunity - |
| Magnetic Field - |
| Magnetic Field - |
| Voltage Dips - |
| Voltage Dips - |
| Component Power Supply for General Use EN 61204-3 |
| Component Power Supply for General Use EN 61204-3 |
| Nominal Battery Voltage - |
| Nominal Battery Voltage - |
| Battery Voltage Range - |
| Battery Voltage Range - |
| Battery Capacity - |
| Battery Capacity - |
| Battery Charging Mode - |
| Battery Charging Mode - |
| End of Charge Voltage - |
| End of Charge Voltage - |
| Battery Fuse - |
| Battery Fuse - |
| Battery Discharging Voltage Range - |
| Battery Discharging Voltage Range - |
| Battery Charging Current - |
| Battery Charging Current - |
| Battery Current Consumption - |
| Battery Current Consumption - |
| Discharging Current - |
| Discharging Current - |
| Recommended Charging Voltage - |
| Recommended Charging Voltage - |
12V
75W
6.25A
85-264Vac
12V
54W
4.5A
85-264 Vac
12V
85.2W
7.1A
85-264 Vac
12V
15W
1.25A
85-264 Vac
| Model Name | Distributor | Availability | Date Updated |
|---|
Product Overview
Industrial Power
Medical Power
Configurable Power
Industrial Battery Charging
LED Driver
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.
DeltaPSU will use the information you provide on this form to be in touch with you.
To unsubscribe, click the link in our newsletter. We will treat your data with respect.